Figure 5
From: Transverse propagation in an expanded PSpice model for cardiac muscle with gap-junction ion channels

Graphic summary of the results obtained for no gj-channels (0/0) or 100 gj-channels (100/100). The number of parallel chains is given on the abscissa. A: TPT measured. B: Transverse velocity calculated from the TPT and distance traveled. C: Overall velocity calculated from the TPT and distance traveled. The myocardial cells were assumed to be 150 μm in length and 16 μm in diameter.