Skip to main content

Table 1 Mechanical properties assigned to a hypothetical solid plate and the resulting micromotion seen at the osteotomy site

From: Evaluation of stiffness-matched, 3D-printed, NiTi mandibular graft fixation in an ovine model

Plate

Bottom area micromotion, μm

Top area micromotion, μm

Bulk Ti64, 120 GPa

14

2.3

Bulk NiTi, 62.5 GPa

27

33

Bulk, 30 GPa

18

15.9

Bulk, 10 GPa

23.5

32.5

Bulk, 5 GPa

38

45

Porous plate (38%) Ti64, 120 GPa

32

37

Porous plate (38%) NiTi, 62.5 GPa

36

44