Skip to main content

Table 1 Overall and intersex distribution of ocular biometric parameters in patients with nuclear cataract

From: SS-OCT-based ocular biometric characteristics of patients with nuclear cataract

Ocular parameters

Male

Female

P value

Total

Age (yr)

68.83 ± 11.00

70.93 ± 9.00

0.005b

70.03 ± 9.96

Axial length (mm)

24.20 ± 1.64

23.71 ± 1.97

0.000b

23.92 ± 1.85

Anterior chamber depth (mm)

3.20 ± 0.45

2.97 ± 0.46

0.000a

3.07 ± 0.47

Lens thickness (mm)

4.46 ± 0.53

4.51 ± 0.48

0.080a

4.49 ± 0.50

White-to-white (mm)

11.81 ± 0.43

11.55 ± 0.42

0.000b

11.66 ± 0.44

Central corneal thickness (μm)

538.09 ± 33.40

531.35 ± 32.17

0.000a

534.25 ± 32.86

Pupil diameter (mm)

3.53 ± 1.15

3.69 ± 1.26

0.009b

3.60 ± 1.21

Angle alpha (mm)

0.46 ± 0.22

0.49 ± 0.28

0.201b

0.48 ± 0.25

Angle kappa (mm)

0.30 ± 0.22

0.29 ± 0.21

0.853b

0.30 ± 0.21

Mean anterior keratometry (D)

44.00 ± 1.64

44.88 ± 1.50

0.000a

44.50 ± 1.62

Anterior flat keratometry (D)

43.47 ± 1.64

44.37 ± 1.51

0.000a

43.99 ± 1.63

Anterior steep keratometry (D)

44.56 ± 1.73

45.41 ± 1.61

0.000a

45.04 ± 1.72

Anterior corneal astigmatism (D)

1.08 ± 0.78

1.05 ± 0.82

0.294b

1.07 ± 0.80

Mean posterior keratometry (D)

5.89 ± 0.23

6.02 ± 0.22

0.000a

5.96 ± 0.24

Posterior flat keratometry (D)

5.78 ± 0.23

5.90 ± 0.22

0.000a

5.85 ± 0.23

Posterior steep keratometry (D)

6.00 ± 0.25

6.15 ± 0.26

0.000b

6.09 ± 0.26

Posterior corneal astigmatism (D)

0.23 ± 0.13

0.25 ± 0.15

0.135b

0.24 ± 0.14

Mean total keratometry (D)

44.02 ± 1.69

44.87 ± 1.65

0.000b

44.51 ± 1.72

Total flat keratometry (D)

43.44 ± 1.70

44.30 ± 1.65

0.000b

43.93 ± 1.73

Total steep keratometry (D)

44.63 ± 1.77

45.46 ± 1.76

0.000b

45.10 ± 1.91

Total corneal astigmatism (D)

1.19 ± 0.83

1.16 ± 0.85

0.338b

1.17 ± 0.84

  1. a Independent sample t test; bMann–Whitney U test